Fixing Bell Mouths Bailing Out Water From The Trenches For Making New Connections In Fully Charged Pipe-lines Including ...
Procurement Summary
Location
Organisation Name
Deadline
Gohana, Haryana, India
PUBLIC HEALTH ENGINEERING DEPARTMENT
30th Jun, 2026
Purchaser's Detail
Fixing Bell Mouths Bailing Out Water From The Trenches For Making New Connections In Fully Charged Pipe-lines Including Cleaning Trimming And Dressing The Trenches To Correct Alignment And Grade As Required By The Engineer-in-charge. Size Of The Main With Which Connection Is To Be Made. 1. Up To 200 Mm Internal Diametre ,manhole Chambers Providing And Fixing Sfrc Manhole Covers And Frames Marked With Is: 12592 Including Setting The Same To Correct Lines And Levels In 1:3 Cement Sand Mortar Over Manhole Including Carriage Loading Unloading Stacking Handling Re-handling Etc. Complete In All Respects To The Satisfaction To The Engineer-in-charge. 1. Type:- Extra Heavy Duty Set (ehd-35) 560mm Clear Opening, Earth Work In Excavation By Mechanical Means (hydraulic Excavator)/manual Means Over Areas (exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sqm On Plan) Including Getting Out And Disposal Of Excavated Earth Lead Up To 50 M And Lift Up To 1.5 M, As Directed By Engineer-in-charge. 1. All Kinds Of Soil ,demolishing Cement Concrete Manually/ By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In - Charge. 2. Nominal Concrete 1:2:4 Or Leaner Mix (i/c Equivalent Design Mix) Cement Concrete (cast In Situ) Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Below Plinth Level And Up To Floor Iv Level: 6. 1:4:8 (1 Cement : 4 Coarse Sand (zone-iii) : 8 Graded Stone Aggregate 40 Mm Nominal Size) .,steel Reinforcement Steel Reinforcement For R.c.c. Work, Where Not Included In The Complete Rate Of Rcc, Including Straightening, Cutting, Bending, Placing In Position, Binding, Wastage, Overlaps, Welded Joints, Spacer Bars, Chairs, Stays, Hangers And Annealed Steel Wire Etc. Complete In All Respect Below Plinth Level Note: Reinforcement Shall Be Measured In Length Including Hooks, If Any, Separately For Different Diameters As Actually Used In Work , Excluding Overlaps. Wastage, Overlaps, Couplings, Welded Joints, Spacer Bars, Chairs, Stays, Hangers And Annealed Steel Wire Or Other Methods Of Binding & Placing Shall Not Be Measured And Cost Of These Items Shall Be Deemed To Be Included In The Rates For Reinforcement. 6. Thermo-mechanically Treated Bars Of Grade Fe-500d Or More,brick Work Brick Work With Common Burnt Clay Non-modular Bricks Of Class Designation 10.5 In Superstructure Above Plinth Level Up To Floor Iv Level In All Shapes And Sizes In : 1. Cement Mortar 1:4 (1 Cement : 4 Coarse Sand)
Other Information
Notice Type
RefID
Last Date Of Submission
Opening Date
tender
45705912
30th Jun, 2026
Refer To Document
Cost
Document Cost
EMD
Estimated Cost
Refer Documents
Refer Documents
Refer Documents